目的:探讨自动分割方法对实时心脏磁共振成像(MRI)左心室功能分析的可行性。方法:采集12名自愿者从心尖层到基底层实时MRI心脏成像数据,运用差异图像、Hough变换及K均值聚类的自动分割方法分割左心室,由两名具有1年以上心脏数据分析经验的观察者(观察者1和观察者2)运用自动分割和手动分割方法获取左心室舒张末期容量(EDV)、收缩末期容量(ESV)、每博血量(SV)和射血分数(EF)等功能参数,评价心脏实时MRI自动分割方法分析左心室功能的可行性。结果:自动分割法可以对舒张末期和收缩末期图像进行分割,但与手动分割方法相比,实际分割曲线仍存在部分差异;两位观察者手动或自动分割法采集的ESV、SV及EF数据差异有统计学意义(P<0.05),EDV差异无统计学意义(P>0.05)。结论:心脏实时MRI自动分割方法能够对左心室EDV功能参数进行分析。
Objective: To investigate the feasibility of automatic segmentation method on left ventricle function analysis of real-time cardiac MRI. Methods: Cardiac magnetic resonance data of 12 volunteers were collected. The automatic segmentation methods of subtraction image,Hough transformation and K-mean clustering were used to segment left ventricle; two observers( observer 1 and observer 2)with more than one year heart disease data analysis experience to gain EDV,ESV,sSV and EF by means of automatic segmentation and manual segmentation,then evaluating the feasibility of automatic segmentation method on left ventricle function analysis of real-time cardiac MRI. Results: The result shows that EDV without statistical significant difference,ESV,SV and EF data collected manually or automatically with statistical significant difference( P < 0. 05). EDV difference showed no statistical significance( P > 0. 05). Conclusion: Automatic segmentation method could analyze the EDV function of left ventricle.
关键词(KeyWords):
心脏;磁共振成像;心室功能,左;射血分数
heart;magnetic resonance imaging;ventricular function,left;ejection fraction
基金项目(Foundation): 国家自然科学基金(81660298);国家自然科学基金地区科学基金(81460206);; 贵州医科大学2015年高等学校大学生创新创业训练计划(201510660004)
作者(Author):
杨帆,李洋,陈波,何艳,谢弘,雷平贵
YANG Fan,LI Yang,CHEN Bo,HE Yan,XIE hong,LEI Pinggui
DOI: 10.19367/j.cnki.1000-2707.2017.01.008
参考文献(References):
- [1]Myerson SG,Holloway CJ,Francis JM,et al.Cardiovascular magnetic resonance(CMR)-An update and review[J].Progress in Nuclear Magnetic Resonance Spectroscopy,2011(3):213-222.
- [2]Matsumoto H,Matsuda T,Miyamoto K,et al.Feasibility of free-breathing late gadolinium-enhanced cardiovascular MRI for assessment of myocardial infarction:Navigatorgated versus single-shot imaging[J].International Journal of Cardiology,2013(1):94-99.
- [3]Zhu XM,Schwab F,Marcus R,et al.Feasibility of freebreathing,GRAPPA-based,real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3 T[J].European Journal of Radiology,2015(84):849-855.
- [4]Moghari MH,Chan RH,Hong SN,et al.Free-breathing cardiac MR with a fixed navigator efficiency using adaptive gating window size[J].Magnetic Resonance in Medincine,2012(6):1866-1875.
- [5]Rasper M,Gramer BM,Settles M,et al.Dual-source RF transmission in cardiac SSFP imaging at 3 T:systematic spatial evaluation of image quality improvement compared to conventional RF transmission[J].Clinical Imaging,2015(2):231-236.
- [6]Moghari MH,Chan RH,Hong SN,et al.Free-breathing cardiac MR with a fixed navigator efficiency using adaptive gating window size[J].Magnetic Resonance in Medincine,2012(6):1866-1875.
- [7]Beer M,Stamm H,Machann W,et al.Free breathing cardiac real-time cine MR without ECG triggering[J].Int J Cardiol,2010(2):380-382.
- [8]Otsu,N.Athreshold selection method from gray-level histograms[J].Automatica,1975(11):23-27.
- [9]Limberger FA,Oliveira MM.Real-time detection of planar regions in unorganized point clouds[J].Pattern Recognition,2015(6):2043-2053.
- [10]Dhanachandra N,Manglem K,Chanu YJ.Image segmentation using K-means clustering algorithm and subtractive clustering algorithm[J].Procedia Computer Science,2015(54):764-771.
- [11]Nguyen C,Kuoy E,Ruehm S,et al.Reliability and reproducibility of quantitative assessment of left ventricular function and volumes with 3-slice segmentation of cine steady-state free precession short axis images[J].European Journal of Radiology,2015(7):1249-1258.
- [12]Cross R,Olivier L,O’Brien K,et al.Improved workflow for quantification of left ventricular volumes and mass using free-breathing motion corrected cine imaging[J].Journal of Cardiovascular Magnetic Resonance,2016(1):1-12.
文章评论(Comment):
|
||||||||||||||||||
|